MENU

composit boiler design

We founded in 1988, with 32 years'experience in research development and manufacture of industrial boiler. Our boiler are saled for more than 100 countries and regions like Egypt, Ethiopia, Congo, Mauritius, Tanzania,South Africa, Mexico, Ireland, Indonesia etc.

  • Hold the ASME "S" and "U" Certificates and have earned ISO9001:2000 Certification.
  • High efficiency, low back pressure, ultra-low NOx emissions.
  • Elegant design with low surface temperature and low heat dissipation
  • Covers an area of 150 thousand square meters, with an annual production capacity of 2000 industrial boilers and 25000 tons of steam.

7*24 hours online service:zhulin@zozen.com

Get Free Quote

OUR PRODUCTS

Explore Recent Work

Modular composite boiler - Alfa Lav

The boiler design has integrated pin tube elements. The pin tube elements support both the furnace and the boiler top plate. The design has been significantly optimised to achieve lower weight and improved strength. The result: longer lifetime of the pin tube by a factor of 8. Description Aalborg OC is a high quality composite boiler design

Composite steam boil

Composite boiler. By Lars Josefsson. Composite boilers are combination of oil-fired boilers and exhaust gas economizers. When the diesel engine is at full load the fuel oil burner only starts if the steam demand exceeds the steam production achieved from the diesel engines exhaust gases.

Boiler and Pressure Vessel (BPV) Services Selection Gui

Boiler and pressure vessel (BPV) service providers specialize in the repair, rebuilding, maintenance, installation, and on- site construction of boilers, pressure vessels, piping, and safety valves. They may additionally provide cleaning, calibration, failure analysis, component testing, and part

Composite Boile

The Cochran boiler whose working pressure is normally of the order of 7 bar is available in various types and arrangements, some of which are: Simple pass composite boilers, i.e., one pass of the exhaust gases and two uptakes, one for the oil fired system and one for exhaust system. Double pass composite boilers, i.e., two passes for the

Boilers: A Practical Reference - 1st Edition - Kum

Boilers: A Practical Reference is the result of those requests, providing a user-friendly encyclopedic format with more than 500 entries and nearly the same number of supporting illustrations. Written for practicing engineers and dealing with practical issues rather than theory, this reference focuses exclusively on water tube boilers found in

Compost Water Heater - Renewable Energy - MOTHER EARTH NE

MOTHER EARTH NEWS' newest compost water heater mound shown here partially completed is a low, rectangular heap with sloping sides (a shape that eliminates the need for a cage) and two flat coils

Boiler Design: Composition, Benefits, & How to Sta

A Steam boiler is a steel pressure container in which water under pressure is transformed into steam by the use of combustion. In other words, the boiler is just a heat exchanger which uses radiant heat and hot flue fumes, released from burning fuel, to produce vapor and hot water for heating and processing loads.

Water Tube Boilers, Hut Type Composite Boiler, Baby Boil

Water Tube Boilers, Hut Type Composite Boiler, Baby Boiler, Smoke Tube Boiler, Steam Generator, Mumbai, India: Design of Furnace volume & arrangement of water wall tubes gives more heating surface in radiant zone to achieve maximum heat & complete combustion also avoid carry-over blockage in …

MODEL BOILERS - Plans for Everythi

File Size: 776KB MODEL BOILERS Figure 79 shows a great improvement in design. The boiler is entirely enclosed, except at one end, so that the hot gases get right round the barrel, and the effective heating surface has been more than doubled by fitting a number of water-tubes, aaa, bbbb, which lie right in the flames, and absorb much heat which would otherwise

Composite Marine Boiler CMB-HF - SAAC

Boiler data Steam capacity fired section t/h Steam capacity * exhaust gas section t/h Design pressure Mpa Main engine mm A mm B** mm Dry weight*** kg Water content at NWL m3 7.0 7.0 1.0 MAN B&W 12 K98 ME, at 90 % MCR ISO condition 5,450 11,300 94,000 63.0 3.0 3.0 1.0 MAN B&W 8 K80 MC-C6, at 85 % MCR ISO condition 3,550 8,600 35,500 17.5

Composite Marine Boilers from SAAC

The CMB-HF is a combined horizontal exhaust gas and three-pass oil fired boiler. Due to the third pass in the convection part in the oil fired section the efficiency is the highest possible for marine boilers. The heat transfer in the oil fired section is performed through the corrugated/plain flame tube furnace and a number of plain smoke tubes.

What Can I Do For You?

Send us your inquiry
Leave Us Message

You can send a message to us by this email to zhulin@zozen.com

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration
Are You Looking for A Consultant? ONLINE SERVICE
totop