MENU

fire tube boiler maximum capacity

We founded in 1988, with 32 years'experience in research development and manufacture of industrial boiler. Our boiler are saled for more than 100 countries and regions like Egypt, Ethiopia, Congo, Mauritius, Tanzania,South Africa, Mexico, Ireland, Indonesia etc.

  • Hold the ASME "S" and "U" Certificates and have earned ISO9001:2000 Certification.
  • High efficiency, low back pressure, ultra-low NOx emissions.
  • Elegant design with low surface temperature and low heat dissipation
  • Covers an area of 150 thousand square meters, with an annual production capacity of 2000 industrial boilers and 25000 tons of steam.

7*24 hours online service:zhulin@zozen.com

Get Free Quote

OUR PRODUCTS

Explore Recent Work

Water-tube or fire-tube condensing boiler, which is t

In a water-tube boiler, it contains a minimal amount of water at any given time. It may be just one-tenth the volume of a fire tube boiler, which requires a larger volume of water to act as a heat shield so that metal in the boiler doesn’t melt and create problems. When fire tube boilers run low on water, the metal in the boilers shrinks.

How Fire Tube Lancashire Boiler Works - Maintenan

Internal fire tube having 2 in number generally used. We can say it has two internal flow tubes whose diameter that is .4 times the size of the Cylindrical shell. The maximum working pressure is 16 bar. The steam capacity of this boiler is 9000kg/h. And the efficiency is 50 to 70%. So these are the specifications of the Lancashire boiler and

Fire Tube Boiler Capacity Calculation--Z

Fire Tube Boiler Capacity Calculation 2018-08-03 08:43:52. A fire-tube boiler is a type of boiler in which hot gases pass from a fire through one or (many) more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.

Fire Tube Boiler - Construction, Types and Its Worki

Fire Tube Boiler Diagram. These boilers include a water level indicator; a pressure gauge, steam stop tap security tap, & a manhole like mountings for providing security as well as simplicity of working. The Fuel burns on the grate of the firebox in the boiler and the resultant hot-flue gases are permitted to flow in the region of cross tubes.

What is the max pressure and capacity in fire tube boil

the maximum pressure and the capacity in the fire tube boiler are usually depends on the model design and specified by the manufacturers in the manufacturer manual.

Fire Tube Boile

A/E Name Issue Description. A/E Project No.Month 00, 0000. The University of Texas FIRE TUBE STEAM BOILERS . MD Anderson Cancer Center23 52 39 . MS2020051510 OF 10

Boiler Capacity - Engineering ToolB

Boiler load - the capacity of a steam boiler - is often rated as boiler horse powers, lbs of steam delivered per hour, or BTU. a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as

Making sense of boiler ratings - HPAC Magazi

Aug 16, 2017· For example, if we have a natural gas boiler with an input rating of 100,000 Btu/h and a heating capacity of 85,000, we would have a steady state efficiency of 85 per cent. This steady state can only be measured when the boiler is at full load and all the conditions, such as return water temperature, air temperature, air/fuel ration, and so on

Section 23 52 39 - FIRE-TUBE BOILERS - Veterans Affairs

· W

· Web viewAt Maximum Required Output: On each fuel at site altitude, with and without economizer (if applicable) in service, at 15 percent excess air. Data must include fuel and steam flow, boiler flue gas outlet temperature, economizer (if provided) flue gas outlet temperature, steam quality, boiler efficiency, furnace pressures, and predicted boiler radiation and unaccounted losses, feedwater and flue

Boiler Formulas - Johnston Boil

Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP Boiler Horsepower BHP = (LB/HR*fe)/34.5 Lb/Hr Pounds per Hour BHP = 21500 * 1.08 / …

BOILER EFFICIENCY GUIDE - Cleaver-Broo

not need high maintenance, boiler tube, add-on devices if the boiler is designed for optimum flue gas velocities in the first place. Each boiler pass should be designed with a cross sectional area to achieve optimal flue gas velocity, which in turn maximizes heat transfer while also minimizing performance robbing soot build-up within the tubes.

What Can I Do For You?

Send us your inquiry
Leave Us Message

You can send a message to us by this email to zhulin@zozen.com

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration
Are You Looking for A Consultant? ONLINE SERVICE
totop